Search results for "Doppler sonography"

showing 10 items of 17 documents

Umbilical cord cysts: evaluation with different 3-dimensional sonographic modes.

2010

Objective. The purpose of this series was to determine whether the use of different 3-dimensional (3D) sonographic modes allows better definition of umbilical cord cysts and pseudocysts in utero. Methods. Two cases of umbilical cord cysts and 1 of a pseudocyst were analyzed and compared with 2-dimensional (2D), 3D, angiopower Doppler, tomographic ultrasound imaging (TUI), virtual organ computer-aided analysis (VOCAL), and automatic volume calculation (AVC) sonographic modes. All cases were followed during pregnancy. A karyotype analysis was also obtained. Results. Three-dimensional sonography, TUI, and VOCAL allowed clear visualization and evaluation of the sizes, locations, and numbers of …

AdultFetusmedicine.medical_specialtyRadiological and Ultrasound Technologybusiness.industryReproducibility of ResultsUmbilical cordSensitivity and SpecificitySurface modeUmbilical CordDoppler sonographyYoung Adultmedicine.anatomical_structureImaging Three-DimensionalImage Interpretation Computer-AssistedmedicineUltrasound imagingHumansRadiology Nuclear Medicine and imagingFemaleRadiologyUrachal CystbusinessUltrasonographyJournal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine
researchProduct

Contrast-enhanced transcranial Doppler ultrasonography in the diagnosis of brain death

2013

The diagnosis of brain death (BD) is based on clinical criteria including deep coma, brain stem areflexia and apnoea. Depending on different local guidelines, confirmatory technical tests are sometimes mandatory.1 Since the 1990s, transcranial Doppler sonography (TCD) has found its place in these circumstances and fulfils most of the criteria of an ‘ideal test’ in confirming BD. To confirm intracranial circulatory arrest (CA) with Doppler sonography, typical flow patterns must be recorded in bilateral intracranial and extracranial brain-supplying arteries.2 A completely absent intracranial flow signal is not a reliable sign to determine CA because this can be due to transmission problems. I…

AdultMaleBrain Deathmedicine.medical_specialtyAdolescentSystoleUltrasonography Doppler TranscranialContrast MediaPhysical examinationYoung AdultEvoked Potentials SomatosensoryIntensive careTemporal bonemedicineHumansChildAgedAged 80 and overBrain deadMicrobubblesmedicine.diagnostic_testbusiness.industryHead injuryUltrasoundElectroencephalographyMiddle Agedmedicine.diseaseTranscranial Doppler ultrasonographyPsychiatry and Mental healthDoppler sonographyCerebrovascular CirculationFemaleSurgeryNeurology (clinical)RadiologybusinessJournal of Neurology, Neurosurgery & Psychiatry
researchProduct

Diagnostic accuracy of current sonographic criteria for the detection of outflow abnormalities in the internal jugular veins

2012

Objectives: This study was aimed at evaluation of the diagnostic value of Doppler sonography for the assessment of abnormalities in the internal jugular veins (IJVs). Method: One hundred and sixteen IJVs were assessed in 58 patients with associated multiple sclerosis. Findings of Doppler sonography were compared with results of the reference test: catheter venography. Results: At least one positive extracranial sonographic criterion suggesting venous abnormality was found in 92.2% of the assessed veins. Yet, sensitivity, specificity, positive and negative predictive values of sonography were low: 93.4%, 12.0%, 79.4% and 33.3% for at least one positive criterion, and for at least two positiv…

AdultMalemedicine.medical_specialtyMultiple SclerosisDiagnostic accuracySensitivity and SpecificitymedicineHumansUltrasonography Doppler ColorAgedphlebographybusiness.industryDoppler ultrasonoundGeneral MedicineMiddle Agedmedicine.diseaseDoppler sonographyFemaleOutflowDoppler ultrasoundRadiologyJugular VeinsCardiology and Cardiovascular MedicineVenous malformationbusinessvenous malformationPhlebology : the journal of venous disease
researchProduct

Extracranial Venous Drainage Pattern in Multiple Sclerosis and Healthy Controls: Application of the 2011 Diagnostic Criteria for Chronic Cerebrospina…

2015

The etiology of multiple sclerosis (MS) is still largely unknown and it has been proposed that an impaired venous drainage from the central nervous system, defined as chronic cerebrospinal venous insufficiency (CCSVI), may play a role in this. We investigated the prevalence of extracranial venous drainage pattern alterations in a cohort of MS patients based on the 2011 revised diagnostic criteria for CCSVI. Thirty-nine MS patients and 18 healthy subjects underwent blinded extra-cranial venous echo-color Doppler sonography to reveal the presence of CCSVI. There was no statistically significant difference between MS patients and healthy controls regarding CCSVI prevalence (p value = 0.53). Th…

AdultMalemedicine.medical_specialtyNeurologyChronic cerebrospinal venous insufficiencyUltrasonography Doppler TranscranialTranscranial030204 cardiovascular system & hematologyPathogenesisMultiple sclerosis03 medical and health sciences0302 clinical medicineEcho-color Doppler sonographyInternal medicineCerebral venous outflow; Chronic cerebrospinal venous insufficiency; Echo-color Doppler sonography; Multiple sclerosis; Neurology (clinical); NeurologymedicinePrevalenceHumansUltrasonographybusiness.industryMultiple sclerosisDopplerVenous drainageMiddle Agedmedicine.diseaseSurgerySettore MED/26 - NEUROLOGIADoppler sonographyChronic cerebrospinal venous insufficiencyVenous InsufficiencyNeurologyCase-Control StudiesCohortEtiologyCardiologyFemaleNeurology (clinical)Cerebral venous outflowbusiness030217 neurology & neurosurgery
researchProduct

Evaluation of collateral flow capacity in patients with vascular or tumorous lesions of the skull base by Doppler sonography

1991

In 12 patients with vascular or tumorous lesions of the skull base, the collateral flow capacity was examined by transcranial Doppler sonography and carotid compression studies. In four patients no cross flow mechanism was found, in two patients the test remained unclear, and in six patients the examination suggested a good collateral flow capacity. However, for this application of Doppler sonography no borderlines have yet been defined and thus interpretation is difficult. Intraoperative Doppler sonography was used in five patients and proved to be helpful for localisation of the internal carotid artery within skull base tumors.

AdultMalemedicine.medical_specialtySkull NeoplasmsCerebral arteriesCollateral CirculationAneurysmmedicine.arteryPressuremedicineHumansAgedUltrasonographyBrain Neoplasmsbusiness.industryGeneral MedicineCerebral ArteriesMiddle AgedCollateral circulationmedicine.diseaseCerebrovascular DisordersDoppler sonographySkullCarotid ArteriesCollateral flowmedicine.anatomical_structureCerebrovascular Circulationcardiovascular systemFemaleSurgeryNeurology (clinical)RadiologyNeurosurgeryInternal carotid arterybusinessNeurosurgical Review
researchProduct

Localization of segmental arteries in renal surgery by Doppler sonography.

1982

Abstract To avoid damage to major arteries of the renal parenchyma during nephrotomy, intraoperative Doppler sonography was used experimentally and clinically as an artery finder. In experiments with 7 beagles segmental arteries were detected easily and reliably by sonography, and the arterial course thus indicated correlated perfectly with arteriograms and casts. In a clinical trial the Doppler artery finder was used in 7 patients with staghorn calculi that were removed via the renal pelvis and additional multiple selective nephrotomies. With as many as 7 selective nephrotomies in a single kidney there was no damage to the major arteries in any of these patients. Selective, avascular nephr…

AdultMalemedicine.medical_specialtyUrologymedicine.medical_treatmentNephrectomysymbols.namesakeKidney CalculiDogsRenal Arterymedicine.arterymedicineAnimalsHumansRenal arteryNephrotomyUltrasonographybusiness.industryRenal surgeryNephrectomyDoppler sonographymedicine.anatomical_structuresymbolsRadiologybusinessRenal pelvisDoppler effectArteryThe Journal of urology
researchProduct

Intraluminal Doppler-Sonography: Analysis and “in Vitro Test” of a New Device

1992

In treating patients with coronary heart disease it’ s necessary first to determine what influence the stenose has on the coronary blood flow. This is a prerequisite for any invasive treatment method. Coronary angiography explosures are only partially useful in attaining a functional evaluation of the haemodynamic stenoses.

Coronary angiographymedicine.medical_specialtyIn vitro testbusiness.industryHemodynamicsTreatment methodBlood flowCoronary heart diseaseDoppler sonographyInternal medicineCardiologymedicineNew devicebusiness
researchProduct

Image guidance to improve reliability and data integrity of transcranial Doppler sonography.

2012

Abstract Background Principles and accuracy of image-guided transcranial Doppler (IG TCD) sonography have been published recently. However, it remains open whether combination of image guidance and TCD offers an additional clinical advantage. This study scores the accuracy of conventional TCD examinations and investigates the potential improvement of TCD data integrity and reliability regarding the additional use of IG. Methods Conventional TCD was performed by a group of experienced investigators, who were blinded to images of a navigation system tracking the Doppler probe, whereas an independent observer documented the TCD findings, acquired by the investigators, due to saving spatial dat…

Intracranial Arteriovenous MalformationsMalemedicine.medical_specialtyNeuronavigationUltrasonography Doppler TranscranialMagnetic resonance angiographyNeurosurgical Procedures03 medical and health sciencessymbols.namesake0302 clinical medicinePostoperative Complications030202 anesthesiologyImage Processing Computer-AssistedMedicineHumansVasospasm IntracranialThrombolytic TherapyImage guidanceAgedmedicine.diagnostic_testbusiness.industryData CollectionTranscranial doppler sonographyUltrasoundReproducibility of ResultsGeneral MedicineMiddle AgedSubarachnoid HemorrhageTranscranial DopplerCerebral Angiographycardiovascular systemsymbolsSurgeryFemaleNeurology (clinical)RadiologybusinessDoppler effect030217 neurology & neurosurgeryMagnetic Resonance AngiographyCerebral angiographyDilatation PathologicClinical neurology and neurosurgery
researchProduct

Cerebral lateralisation during signed and spoken language production in children born deaf

2019

Highlights • Children born deaf show typical left-hemisphere dominance during language production. • No evidence of an association between left-lateralisation and language proficiency. • Exposure to auditory speech via a cochlear implant is not a prerequisite for left hemisphere language dominance.

Malelcsh:QP351-495Deafnessmusculoskeletal systemArticlelcsh:Neurophysiology and neuropsychologyotorhinolaryngologic diseasesCochlear implantsHumansfTCDFemaleSign languageChildDominance Cerebralhuman activitiesDeafChildrenLateralisationLanguageFunctional transcranial Doppler sonographyDevelopmental Cognitive Neuroscience
researchProduct

Transcranial Doppler sonography in dementia of Alzheimer type.

1994

The intention of this study was to examine the relation of clinical variables and cognitive dysfunction to cerebrovascular blood flow in a sample of patients with Alzheimer''s disease without any sign or symptom of cardiovascular or cerebrovascular disease. The patients met DSM-III-R criteria for dementia of Alzheimer type. Blood flow velocities in the anterior, middle (MCA) and posterior cerebral arteries were recorded using transcranial Doppler sonography. Several psychometric tests including the Mini-Mental State Examination (MMSE) were performed. The patients’ age correlated significantly with the systolic flow velocity in the left MCA (r = –0.57) explaining 24% of the total variance; t…

Malemedicine.medical_specialtyUltrasonography Doppler TranscranialCognitive NeuroscienceDiseaseNeuropsychological TestsCentral nervous system diseaseDegenerative diseaseAlzheimer DiseaseInternal medicinemedicineHumansAgedAged 80 and overbusiness.industryTranscranial doppler sonographyCognitionBlood flowMiddle Agedmedicine.diseaseSurgeryPsychiatry and Mental healthCerebral blood flowCerebrovascular CirculationCardiologyFemaleGeriatrics and GerontologyAlzheimer's diseasebusinessDementia (Basel, Switzerland)